logo
خانه محصولاتچک وزنه اتوماتیک

Inspection Procedures for Industrial Weighing Systems

Inspection Procedures for Industrial Weighing Systems

جزئیات محصول:
محل منبع: چین
شماره مدل: روشهای بازرسی برای سیستم های توزین صنعتی
پرداخت:
مقدار حداقل تعداد سفارش: 1 ست
قیمت: قابل مذاکره
جزئیات بسته بندی: جعبه
زمان تحویل: 10-30 روز
قابلیت ارائه: 2000 مجموعه در هر ماه
مخاطب
توضیحات محصول جزئیات
Product: Inspection Procedures for Industrial Weighing Systems Weighing Range: Min: 0.1 kg – Max: 50,000 kg (varies by model)
Tolerance (Error Limit): ±0.1% of reading (for Class III) or ±1 division (whichever is stricter) Frequency: Every 6 months (or after 500 hours of operation)
Calibration Weights: Class F1/M1 (OIML R111) with valid certification Temperature Range: -10°C to +40°C (operational), -20°C to +60°C (storage)
Humidity Tolerance: 10% to 90% RH (non-condensing) Load Cell Type: Strain gauge (standard), Capacitive (high precision)
Overload Protection: 150% of max capacity (safety limit) Power Supply: 110–240V AC, 50/60Hz or 24V DC (±5%)
EMC/EMI Resistance: Complies with EN 61326-1 (industrial EMC standards) Repeatability: ±0.05% of applied load (test with 10 repeated measurements)
Linearity Error: ±0.2% of full scale Material Safety: Stainless steel (Grade 316) for corrosive environments
Legal-for-Trade: NTEP, MID (EU), OIML certification (if used in commerce) Calibration Certificate: Must include date, technician, uncertainty, traceability
User Manual: Must cover installation, operation, maintenance, troubleshooting
برجسته کردن:

industrial weighing system inspection,load cell inspection procedures,Mettler Toledo weighing system maintenance

,

load cell inspection procedures

,

Mettler Toledo weighing system maintenance

Inspection Procedures for Industrial Weighing Systems
Comprehensive inspection procedures for industrial weighing systems to ensure accuracy, safety, and compliance with industry standards.
Technical Specifications
Attribute Value
Weighing Range Min: 0.1 kg – Max: 50,000 kg (varies by model)
Tolerance (Error Limit) ±0.1% of reading (for Class III) or ±1 division (whichever is stricter)
Frequency Every 6 months (or after 500 hours of operation)
Calibration Weights Class F1/M1 (OIML R111) with valid certification
Temperature Range -10°C to +40°C (operational), -20°C to +60°C (storage)
Humidity Tolerance 10% to 90% RH (non-condensing)
Load Cell Type Strain gauge (standard), Capacitive (high precision)
Overload Protection 150% of max capacity (safety limit)
Power Supply 110–240V AC, 50/60Hz or 24V DC (±5%)
EMC/EMI Resistance Complies with EN 61326-1 (industrial EMC standards)
Inspection Process Overview
Industrial weighing system inspections involve evaluating mechanical integrity, electronic performance, and overall functionality to maintain measurement reliability and compliance.
Pre-Inspection Checks
  • Visual Inspection: Examine for damage, wear, or corrosion on platform and support structure
  • Cable and Connection Check: Verify all connections are secure and undamaged
  • Foundation and Environment: Assess for stability and environmental factors affecting performance
Calibration and Verification
  • Zero Balance Check: Verify stable zero reading with no load
  • Span Calibration: Test accuracy across weighing range using certified test weights
  • Repeatability Test: Confirm consistent readings with repeated measurements
Functional and Operational Tests
  • Load Cell Performance: Verify proper function and balanced outputs
  • Indicator and Software Check: Test display functionality and data transmission
  • Safety and Overload Test: Confirm proper activation of overload protection
Inspection Procedures for Industrial Weighing Systems 0

اطلاعات تماس
SMARTWEIGH INSTRUMENT CO.,LTD

تماس با شخص: Mrs. Shirley

تلفن: +86-15851932889

فکس: 86-519-68781609

ارسال درخواست خود را به طور مستقیم به ما (0 / 3000)

سایر محصولات